13802656572        sales@wwmater.com
  • High Low Temperature Circulating Device
  • High Low Temperature Circulating Device
  • High Low Temperature Circulating Device
High Low Temperature Circulating Device High Low Temperature Circulating Device High Low Temperature Circulating Device

High Low Temperature Circulating Device

  • "The liquid circulation of the system is closed, with an expansion container, the expansion container is insulated from the liquid circulation system, does not participate in the liquid circulation, but is only mechanically connected, regardless of the temperature of the circulating liquid, the medium in the expansion container always maintains room temperature.
  • Since the entire liquid circulation is a closed system, there is no water vapor absorption at low temperatures and no oil mist at high temperatures."
  • EMAIL   INQUIRY


1、 With an internal circulation tank, the volume of the internal circulation is small (the volume of the internal circulation of most equipment is only 6-10L), the effective power density is large (W/L), the rate of heating and cooling is very fast, and the demand for thermal oil is relatively small.

2、 The equipment adopts wave plate heat exchanger, the heat exchange area is large, the heat exchange speed is fast.
3、Closed liquid circulation: no oil mist volatilization at high temperature, thermal oil will not be oxidized or Browning; At low temperature, it will not absorb water vapor in the air, extend the life of thermal oil, and the use cost is low.
4、The use of PID intelligent control, according to the chemical process automatically adjust the power output, accurate control of the temperature of the reaction process, to meet the reaction process of temperature change requirements.
5、Specially customized circulation pump, can provide the maximum flow rate, produce the least pressure and heat, to achieve the highest heat exchange efficiency, the least system resistance, the least pump system heat, the least system energy consumption.
6、The standard type adopts PLC control, more user-friendly display interface (human-machine interface), simple operation, can display the set temperature of the working process, the exit temperature, the temperature change curve in the cap body, to achieve the program of the rise and fall temperature multi-stage programming.
7、Standard type can set the maximum temperature difference in the kettle body and jacket according to the safety requirements provided by the reactor manufacturer. If the temperature difference between the inside and outside reaches the safety limit value required by the manufacturer, the equipment will automatically stop working and give an alarm to ensure that the reactor will not break because the temperature difference is too large.



Top